Features of TYCORUN 76V 40 Ah Lifepo4 battery for motorcycle battery swap station
- Rated energy up to 3072Wh, long-lasting battery life, reducing frequent charging
- Using lithium iron phosphate battery cells, with multiple protections such as short circuit, overcharge/over-discharge/overcurrent, safer and more stable operation
- Supports 80A continuous discharge and 100A peak discharge (30s), meeting the startup and operation requirements of high-power equipment
- Supports CAN protocol charging management, convenient for intelligent docking of the whole vehicle, and realizes remote monitoring and BMS linkage
- Cycle life ≥ 2000 times, reducing maintenance and replacement costs and improving return on investment
- Wide charging and discharging temperature range (0℃~55℃ charging, -20℃~60℃ discharging), adapting to various climate environments
- Self-discharge ≤3.5%/month, long-term storage can still maintain a good power state
- 1P24S structural design, easy modular integration, adaptable to a variety of electric vehicle systems
TYCORUN customized 76v 40ah Lifepo4 battery uses highly safe lithium iron phosphate cells, has a large capacity of 3072Wh, supports CAN protocol intelligent management, and has a peak discharge capacity of up to 100A, which is suitable for electric motorcycles, electric scooters, and electric tricycles. Its ≥2000 cycle life, wide temperature operating range and low self-discharge characteristics ensure that it is stable and reliable in various complex environments, and is an ideal power solution for improving equipment performance and efficiency.
| Product specifications | |||
| Parameter | Specification | Condition / Note | |
| Connection | 1P24S | – | |
| Nominal voltage | 76.8V | 3.2V×24S | |
| Nominal capacity | 40Ah | At a 0.33C discharge current (25±2°C) | |
| Rated energy (Wh) | 3072Wh | – | |
| Max operating voltage | 87.6V | 3.65V × 24 | |
| Minimum operating voltage | 60V | 2.5V × 24 | |
| Charge method (software) | CAN protocol charging | – | |
| Temperature range (charging) | 0℃ ~ 55℃ | – | |
| Temperature range (discharging) | -20℃ ~ 60℃ | – | |
| Standard charge current | 20A | – | |
| Standard discharge current | 40A | – | |
| Max discharge current (continuous) | 80A | – | |
| Peak discharge current | 100A / 30s | 20℃ to 55℃, ≥50% SOC | |
| AC impedance | ≤60mΩ | SOC=50% At25℃ 1KHz | |
| Static pressure difference during system shipment | ≤30mV | 50% ~ 60% SOC (factory mode) | |
| Self-discharge | ≤3.5%/month | Fresh cell after 3 months, 40%SOC, 25±2°C storage | |
| Working environment humidity | 65% ± 20% | – | |
| Optimum storage temperature | One month | -30℃ ~ 45℃ | Storage ambient humidity;85% ROH, no condensation |
| Six month | -20℃ ~ 30℃ | ||
| Altitude requirement | ≤2000m | – | |
| Shipping SOC | 20~30% SOC | ||
| Cycle life | ≥2000cycles | 25℃±2℃, 0.5C charge, 0.5C discharge, discharge 80% of the measured reference capacity of the battery pack each time, after charging / discharging, each stand for 1h, EOL80%. | |
| Short circuit protection | Automatically disconnects the load after short circuit | Short-circuit the battery’s output positive and negative terminals with a 0.1Ω resistor. | |
| Activation power consumption | ≤40mA | – | |
| Hibernation power consumption | 100uA | – | |
| Low power storage | Shelf time ≥30days | – | |